Problem:
Load
induced bearing failures.
System One Solution: Solid shaft and
oversized bearings carry high-sustained
loads for the life of the pump.
Problem:
Seal
failures due to off BEP operation.
System One Solution: Large diameter
solid shaft with the lowest LD ratio in
the industry (19) provides the stiffness
required to withstand damaging forces and
maintain seal face alignment.
Problem:
Oil
contamination.
System One Solution: Small amounts
of dirt and water can cause complete
bearing failure in a short period of
time.Chesterton labyrinth seals,standard
on the Frame M Pump,keep dirt and moisture
out, prolonging oil and bearing life.
Problem:
Damaging
vibration caused by motor misalignment.
System One Solution:
C-Frame/D-Flange adapters take the time
and guesswork out of motor alignment.
Instant alignment prevents destructive
vibration and reduces labor costs.